Precautions for installation of high current industrial plug
Pubdate: 2021-10-12 10:16:01
Hits: 334
Share :

What should be paid attention to when installing high current industrial plug? If you don't know, it's better to know, which makes it safer for you to install high current industrial plug. Industrial plugs are applicable to industry. They are generally divided into 3 cores, 4 cores, 5 cores, etc. the current is generally divided into 16a, 32a, 63A, 125A, 250A, 420a, etc. the protection grade can be divided into IP44 and IP67, which are relatively conventional. Generally, it is used together with industrial socket and industrial connector. In order to realize frequent commutation of NEMA wiring device, but also realize commutation, the braking and backward acceleration movement must be as small as possible. For this, the commutation device shall be used quickly and the braking device shall be flexible. A socket into which one or more circuit wiring can be inserted, through which various wiring can be inserted to facilitate connection with other circuits. Here's what you should pay attention to when installing high current industrial plug:


1. When installing the high current industrial plug in an obvious position, it is usually installed on the wall of 1.5m ~ 1.8m. If it is to be installed secretly, the high current industrial plug shall not be less than 0.3m from the ground.


If you have children at home, you'd better choose a high current industrial plug with internal automatic fault prevention device to prevent the child from being electrocuted by the high current industrial plug or touching the hole of the high current industrial plug with your fingers.


2。 Whether it is another socket or high current industrial plug, it shall be kept more than 30cm away from the installation position of another socket to avoid mutual interference or leakage of adjacent sockets.


3. When the single-phase three hole high current industrial plug is installed and wired, the holes at the upper end of the high current industrial plug are the grounding holes. These holes need to be firmly connected with the grounding wire. Each line of high current industrial plug must be carefully checked before wiring. Never connect the zero line and grounding line of high current industrial plug incorrectly, which will make the high current industrial plug unusable or short circuit immediately, What's more serious is that electric shock may occur at the moment when the high current industrial plug is inserted.


If you want to know more or have any questions about it, we will help you solve the problem as soon as possible.